11/30/2022 0 Comments Pro 42 alignment software![]() ![]() For multiple measurements always start by performing a new calibration.Scanning has to start from white area on target and finish on white area - using recommended stop sticks and suggested positioning on the ruler makes it easy.We recommend warming-up the instrument before use– simply measure the first line two or three times in a row.Upload data to your ChromaChecker account. Your data is now ready for upload. Use naming convention with target serial number. When measurement is successfully completed, save CxF file on your hard drive. Scan first line - start from BLUE patch on the bottom - move in the direction from BLUE to BLACK on the end of first scanning line.Ĭontinue with second and third etc until finished.Īlways scan in only one direction from the bottom to top of the target! The last scanning line starts with GREEN and ends with RED patch.ĭisplayed on screen patch layout shows ChromaChecker Target rotated 90° clockwise.ĭuring scanning slide your instrument slowly, hold it firmly to avoid shaking: Recommend stop stick (blue element) for B-42 (same length of 4.5" (114 mm)), but has to be placed on opposite side of target. ![]() Make stop stick yourself as it is not delivered with target (optional).įor the B-42 version we recommend the opposite position on the ruler. For i1 Pro and X-42 length of this stop should be around 4.5" (114 mm). This helps to limit the movement of spectrophotometer. Made of plastic tube or any other material. We recommend using a stop stick (blue element placed on the ruler). This Target should be placed at the top of the ruler. Red arrows show recommended alignment of targets and stop sticks (blue stick inside guide to stop i1). Proper calibration procedures have a very strong influence on measurement results.ĭepending which target you are going to use follow instructions bellow: Check if optical patch is free of artifacts and dust. Be sure that instrument is not very cold or hot (store it in its recommended temperature). Remember to clean calibration plate (ceramic tile) before calibration. Place instrument on the calibration plate and calibrate it (press "Calibrate" button). Then select "Measure Chart" in CMYK Printer section. Make sure CMYK Printer is selected under the "Printer" section. This software can be used in demo mode for data capture.ĭownload this software free from the X-Rite web site: Switch software from Basic to Advanced mode. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |